Measuring Co2 Values - Henny Penny SmartCombi GSC62 series Planning And Installation Instructions

Combisteamer (gas)
Hide thumbs Also See for SmartCombi GSC62 series:
Table of Contents

Advertisement

Smart Combi
Classic Combi
6.7.2 Measuring CO
Requirements
Global Foodservice Solutions
4. PressC o m b i Di a l ( 9 ) to open the menu.
The multi-function display (4) shows „Password" and „000" .
5. Press C o m b i Di a l ( 9 ) to enter the password "999".
6. PressC o m b i Di a l ( 9 ) to confirm the selection.
The multi-function display (4) shows "Calibr. gas CO2".
7. Press S t a r t / St o p (8 ) to start the CO
The multi-function display (4) shows "High power", the fan speed and
the cooking chamber temperature.
NOTICE
With floor standing units, you can switch between the upper and the
lower chambers with the s e l e c t bu t t o n (1 3 )"Change chamber".
The multi-function display (4) indicates the selected chamber with an
arrow next to the fan speed.
The CO
content is measured at high power.
2
values
2
The following conditions must be met in order to measure CO
in the cooking chamber:
Cooking chamber door is closed
Burner is at high power
The multi-function display (4) shows a cooking chamber
temperature of 150 °C (302 °F)
The multi-function display (4) shows the fan speed at full power
according to the following table.
WARNING
Risk of suffocation due to carbon monoxide
Safe operation cannot be guaranteed if the CO
the recommended limits.
→ Make sure that the CO
than at high power.
→ Keep within the recommended limits for CO
29, Page
50).
NOTICE
Do not insert the probe during ignition; the CO
be especially high due to the ignition process.
Planning and installation instructions
calibration.
2
content is not within
2
content at low power is 0.5–1 % lower
2
2
values measured will
2
Gas
values
2
content (see
Table
49