3. Unscrew the sealing screw from the pressure measurement
connection on the gas valve.
4. Connect the manometer.
5. Reopen the central gas supply.
6. Switch on the unit.
7. Measure the connection pressure.
The connection pressure should be within the range given in the
following table.
Type of gas
Natural gas E, LL
Liquid gas B, P
Table 25: Connection pressures
NOTICE
Deviations in connection pressure
The appliance may not be used if the connection pressure is above
the range given above (max. 60 mbar). The gas supplier must be
informed that the supply pressure is too high.
Reliable operation cannot be guaranteed if the connection pressure
is below the range given above, (less than 15 mbar). Calculate the
gas supply to ensure that connection pressure during operation is at
least 15 mbar, even when several gas-consuming appliances are
used simultaneously.
8. Close the pressure measuring points tightly while the shut-off valve
is still closed.
9. Check pressure measuring points for leaks.
10. Refit the side panel.
6.6 Checking CO
NOTICE
Open the front cover of the operating manual to see the controls.
Planning and installation instructions
Nominal connec-
Measured con-
tion pressure
nection pressure
20 mbar
15.0–25.0 mbar
50 mbar
15.0–57.5 mbar
/CO values (ClassicCombi)
2
Gas
Action to be
taken
None, no operat-
ing restrictions
None, no operat-
ing restrictions
43