Installation

Before installing
Fire prevention regulations
Installation in buildings
Installing below ground
Minimum clearances
22
3 Installation

3.1 Installation information

NOTICE
Examine the unit for transportation damage. Do not install or use
damaged units.
Remove the protective film from the external panels before using for
the first time.
Remove foam transport protection from the chamber.
NOTICE
Observe the local fire prevention regulations when installing near to
materials that are heat sensitive or endangered by fire.
Covers on top of the unit must be fire-proof.
Units may only be installed on or against fire-proof surfaces and in
compliance with fire prevention regulations.
The floor or table must be able to bear the weight of the unit (see
"Weight", Page
If there is a drainage grating in front of the unit, the customer should fit a
ramp to enable the rack trolley or loading trolley to be pushed across.
NOTICE
When installing the unit in rooms below ground level (cellars), the current
level
local provisions for liquid gas, in particular, are to be observed when
connecting and operating the gas combisteamer.
A minimum clearance of 50 mm (2") must be maintained from walls to
the sides and behind the unit and at least 0.5 m (1.6 ft.) above the unit
for servicing.
Planning and installation instructions
10).
Smart Combi
Classic Combi
Chapter
Global Foodservice Solutions