Start Co2 Calibration - Henny Penny SmartCombi GSC62 series Planning And Installation Instructions

Combisteamer (gas)
Hide thumbs Also See for SmartCombi GSC62 series:
Table of Contents

Advertisement

Gas
6.6.1 Start CO
C L
P Ar
P AS
C O2
H i
C O2
H i
44
calibration
2
WARNING
Possible danger
→ Non-compliance may pose a threat of death or serious injury.
NOTICE
If there is still air in the gas pipeline, display (8) will show the error "71"
(no gas). Repeat the start procedure if this happens.
1. Switch on the unit.
2. Press F L E X I (2).
Display (9) flashes and shows "CL".
3. Rotate the s e t bu t t o n (6), to select "PAr".
4. Press S t a r t / S t o p (5).
0
Display (9) shows "PAS" for password.
Display (8) shows "0".
5. Rotate the s e t bu t t o n (7) to select "999".
6. Press S t a r t / S t o p (5) to confirm the entry.
Display (9) shows "CO2".
With tabletop units: Display (8) flashes and shows "Hi".
With floor standing units: Display (8) flashes and shows "Hi1" for the first
chamber.
NOTICE
With the s e t bu t t o n (7) you can switch between high power "Hi" ("Hi1"
and "Hi2" with floor standing units) and lower power "Lo" ("Lo1" and
"Lo2" with floor standing units).
With floor standing units, you can switch between the upper and the
lower chambers with F L E X I (2).
The CO
content is measured at high power.
2
7. Set high power with the s e t bu t t o n (7). "Hi" ("Hi1" or "Hi2" for floor
standing units).
8. Press S t a r t / S t o p (5) to start CO
St a r t/ St o p LEDs (5) flash.
Planning and installation instructions
Smart Combi
Classic Combi
calibration.
2