4 Electricity
4.1 Power cable requirements
The unit is delivered as standard without a connection cable. A H07RN-F
cable complying with EN standards or, respectively, with the locally
applying provisions, must be used for connecting the unit. The table shows
the length of cable required inside the unit.
Size
615/620
115/120
215/220
4.2 Opening and closing the switch cover
DANGER
Danger due to high voltage
There are voltage-carrying components behind the switch cover.
→ Disconnect the unit from the power supply before opening the switch
cover.
→ Do not operate the unit when the switch cover is open.
1. Pull the hand shower out approx 20 cm.
2. Screw in the hexagonal socket screw (size 5) on the underside of
the switch cover as far as it will go.
3. Press the switch cover lightly and lift approx 20 mm upwards.
4. Raise the switch cover approx 20 mm and lower it again
5. Open the switch cover fully.
6. Check that the seal around the switch cover fits properly and that it
is not damaged.
7. Replace a damaged seal, if necessary.
8. Close the switch cover carefully.
When doing so, ensure that cables are not trapped and that the
cooling fan cannot be obstructed by any cables.
9. Press the switch cover lightly and lift approx 20 mm upwards.
10. Close the switch cover fully and lower it again pressing lightly.
11. Check that the seal around the switch cover fits properly.