Application Examples - Danfoss VLT AutomationDrive FC 360 Quick Manual

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Application Examples

6 Application Examples
6.1.1 AMA
FC
+24 V
12
D IN
18
19
D IN
COM
20
D IN
27
D IN
29
D IN
32
33
D IN
+10 V
50
A IN
53
A IN
54
COM
55
A OUT
42
Table 6.1 AMA with T27 Connected
6.1.2 Speed
FC
+24 V
12
18
D IN
19
D IN
20
COM
27
D IN
29
D IN
32
D IN
33
D IN
+10 V
50
+
A IN
53
A IN
54
COM
55
-
A OUT
42
0 ~10 V
Table 6.2 Analog Speed Reference (Voltage)
MG06A602
Quick Guide
Parameters
Function
Setting
Parameter 1-29 A
[1] Enable
utomatic Motor
complete
Adaptation
AMA
(AMA)
Parameter 5-12 T
[2]* Coast
erminal 27
inverse
Digital Input
*=Default value
Notes/comments: Set
parameter group 1-2* Motor
Data according to motor
specifications.
NOTICE
If terminal 12 and 27 are
not connected, set
parameter 5-12 Terminal 27
Digital Input to [0] No
operation.
Parameters
Function
Setting
Parameter 6-10 T
erminal 53 Low
0.07 V*
Voltage
Parameter 6-11 T
erminal 53 High
10 V*
Voltage
Parameter 6-14 T
erminal 53 Low
0
Ref./Feedb. Value
Parameter 6-15 T
erminal 53 High
1500
Ref./Feedb. Value
Parameter 6-19 T
[1] Voltage
erminal 53 mode
*=Default value
Notes/comments:
Danfoss A/S © 04/2015 All rights reserved.
FC
+24 V
12
D IN
18
D IN
19
COM
20
D IN
27
D IN
29
D IN
32
D IN
33
+10 V
50
+
A IN
53
A IN
54
COM
55
-
A OUT
42
4 - 20mA
Table 6.3 Analog Speed Reference (Current)
FC
+24 V
12
D IN
18
D IN
19
COM
20
D IN
27
D IN
29
D IN
32
D IN
33
+10 V
50
A IN
53
≈ 5kΩ
A IN
54
COM
55
A OUT
42
Table 6.4 Speed Reference (Using a Manual Potentiometer)
Parameters
Function
Setting
Parameter 6-12 T
erminal 53 Low
4 mA*
Current
Parameter 6-13 T
erminal 53 High
20 mA*
Current
Parameter 6-14 T
erminal 53 Low
0
Ref./Feedb. Value
Parameter 6-15 T
erminal 53 High
1500
Ref./Feedb. Value
Parameter 6-19 T
[0] current
erminal 53 mode
*=Default value
Notes/comments:
Parameters
Function
Setting
Parameter 6-10 T
erminal 53 Low
0.07 V*
Voltage
Parameter 6-11 T
erminal 53 High
10 V*
Voltage
Parameter 6-14 T
erminal 53 Low
0
Ref./Feedb. Value
Parameter 6-15 T
erminal 53 High
1500
Ref./Feedb. Value
Parameter 6-19 T
[1] voltage
erminal 53 mode
*=Default value