Quick Start
Application
Conveyors, extruders
Description
For running at a stable speed by a voltage reference signal.
FC 360
3
3
+24V 12
DI1
18
DI2
19
DI3
27
DI4
29
DI5
32
DI6
33
DI7
31
COM 20
+10V 50
AI1
53
54
AI2
COM 55
AO1
45
AO2
42
1
R1
2
3
4
R2
5
6
Parameter settings
Parameter
Parameter 1-00 Configuration Mode
Parameter 3-00 Reference Range
Parameter 3-15 Reference 1 Source
Parameter 4-12 Motor Speed Low Limit
[Hz]
Parameter 4-14 Motor Speed High Limit
[Hz]
Parameter 5-10 Terminal 18 Digital Input
Parameter 5-12 Terminal 27 Digital Input
Parameter 5-40 Function Relay (Relay 1
Selection)
Parameter 5-40 Function Relay (Relay 2
Selection)
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-19 Terminal 53 mode
Parameter 6-70 Terminal 45 Mode
Parameter 6-71 Terminal 45 Analog
Output
Parameter 6-90 Terminal 42 Mode
Parameter 6-91 Terminal 42 Analog
Output
Table 3.4 Speed Open Loop
12
Start
Coast inverse
Option/value
[0] Speed Open Loop
[0] Min–Max
[1] AI 53
25.0 Hz
50.0 Hz
[8] Start
[2] Coast Inverse
[5] Running
[9] Alarm
0.07 V
10 V
[1] Voltage Mode
[0] 0–20 mA
[100] Output frequency
[0] 0–20 mA
[103] Motor Current
Danfoss A/S © 04/2015 All rights reserved.
®
VLT
AutomationDrive FC 360
Application
Machine tools, texturizers
Description
For precise speed applications with 24 V encoder feedback
FC 360
+24 V 12
DI1
18
DI2
19
DI3
27
DI4
29
DI5
32
DI6
33
DI7
31
COM 20
50
+10 V
AI1
53
54
AI2
COM 55
45
AO1
AO2
42
R1
R2
Parameter settings
Parameter
Parameter 1-00 Configuration Mode
Parameter 3-00 Reference Range
Parameter 3-15 Reference 1 Source
Parameter 3-16 Reference 2 Source
Parameter 4-12 Motor Speed Low Limit
[Hz]
Parameter 4-14 Motor Speed High Limit
[Hz]
Parameter 5-10 Terminal 18 Digital Input
Parameter 5-12 Terminal 27 Digital Input
Parameter 5-14 Terminal 32 Digital Input
Parameter 5-15 Terminal 33 Digital Input
Parameter 5-40 Function Relay (Relay 1
Selection)
Parameter 5-40 Function Relay (Relay 2
Selection)
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-19 Terminal 53 mode
Parameter 6-70 Terminal 45 Mode
Parameter 6-71 Terminal 45 Analog
Output
Parameter 6-90 Terminal 42 Mode
Parameter 6-91 Terminal 42 Analog
Output
Start
Coast inverse
B
A
1
2
3
4
5
6
Option/value
[1] Speed Close Loop
[0] Min–Max
[1] AI 53
[11] Local Bus Ref
20.0 Hz
50.0 Hz
[8] Start
[2] Coast Inverse
[82] Encoder input B
[81] Encoder input A
[5] Running
[9] Alarm
0.07 V
10 V
[1] Voltage Mode
[0] 0–20 mA
[100] Output frequency
[0] 0–20 mA
[103] Motor Current
MG06A602