Connection Tightening Torques - Danfoss VLT AutomationDrive FC 360 Quick Manual

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Specifications

8.4 Connection Tightening Torques

Make sure to use the right torques when tightening all electrical connections. Too low or too high torque may cause
electrical connection problems. Use a torque wrench to ensure that correct torques are applied.
Enclosure
size
J1
J2
J3
J4
J5
J6
J7
J7
Table 8.5 Tightening Torques
8
8
56
VLT
Power [kW]
Mains
0.37–2.2
0.8
3.0–5.5
0.8
7.5
0.8
11–15
1.2
18.5–22
1.2
30–45
3.5
55
12
75
14
Danfoss A/S © 04/2015 All rights reserved.
®
AutomationDrive FC 360
Torque [Nm]
Motor
DC connection
0.8
0.8
0.8
0.8
0.8
0.8
1.2
1.2
1.2
1.2
3.5
3.5
12
12
14
14
Brake
Ground
0.8
3
0.8
3
0.8
3
1.2
1.6
1.2
1.6
2.5
2.5
2.5
Relay
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
MG06A602