Danfoss VLT AutomationDrive FC 360 Quick Manual page 52

Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Specifications
Frequency converter typical
shaft output [kW]
Enclosure protection rating
IP20
Output current
Continuous (3x380–440 V)
[A]
Continuous (3x441–480 V)
[A]
Intermittent (60 s overload)
[A]
Continuous kVA (400 V AC)
[kVA]
Continuous kVA (480 V AC)
[kVA]
Maximum input current
Continuous (3x380–440 V)
[A]
Continuous (3x441–480 V)
[A]
8
8
Intermittent (60 s overload)
[A]
Additional specifications
Maximum cable size (mains,
motor, brake) [mm
Estimated power loss at
rated maximum load [W]
Weight [kg], enclosure
protection rating IP20
Efficiency [%]
3)
Table 8.3 Mains Supply 3x380–480 V AC - Normal Duty
1) Heavy duty=150–160% current during 60 s, Normal duty=110% current during 60 s.
2) The typical power loss is at nominal load conditions and expected to be within
cable conditions).
Values are based on a typical motor efficiency (IE2/IE3 border line). Motors with lower efficiency add to the power loss in the frequency
converter and motors with high efficiency reduce power loss.
Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses
may rise. LCP and typical control card power consumptions are included. Further options and customer load may add up to 30 W to the
losses (though typical only 4 W extra for a fully loaded control card, fieldbus, or options for slot B).
For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency.
3) Measured using 5 m screened motor cables at rated load and rated frequency for enclosure sizes J1–J5, and using 33 m screened
motor cables at rated load and rated frequency for enclosure sizes J6 and J7. For energy efficiency class, see the Ambient Conditions
section in chapter 8.2 General Technical Data. For part load losses, see www.danfoss.com/vltenergyefficiency.
50
VLT
Q11K
Q15K
11
15
J4
J4
23
31
21
27
25.3
34.1
15.94
21.48
17.5
22.4
22.1
29.9
18.4
24.7
24.3
32.9
2
(AWG)]
289.53
393.36
2)
9.4
9.5
97.8
97.8
Danfoss A/S © 04/2015 All rights reserved.
®
AutomationDrive FC 360
Q18K
Q22K
Q30K
18.5
22
30
J5
J5
37
42.5
34
40
40.7
46.8
67.1
25.64
29.45
42.3
28.3
33.3
43.2
35.2
41.5
29.3
34.6
49.3
38.7
45.7
62.7
16(6)
402.83
467.52
630
12.3
12.5
22.4
98.1
97.9
98.1
1)
Q37K
Q45K
37
45
J6
J6
J6
61
73
90
52
65
77
80.3
99
50.6
62.4
54.0
64.0
57
70.3
84.2
60.8
72.7
77.3
92.6
50(1/0)
848
1175
22.5
22.6
98.0
97.7
± 15% (tolerance relates to variety in voltage and
Q55K
Q75K
55
75
J7
J7
106
147
96
124
116.6
161.7
73.4
101.8
79.8
103.1
102.9
140.3
88.8
121.1
113.2
154.3
85(3/0)
1250
1507
37.3
38.7
98.0
98.2
MG06A602