YASKAWA MP2000 Series User Manual page 76

Machine controller. ethernet/ip communication module
Hide thumbs Also See for MP2000 Series:
Table of Contents

Advertisement

5.1 Using the 263IF-01 as a Scanner
5.1.2 Examples of EtherNet/IP Transmission Definition Settings
Size (Byte)
11
Description
Set the same size as Input Size [Byte] of the other device.
The content separated by commas (,) in the string to the left of "$ O=>T RPI,Size,Format" in the EDS
file represents RPI, size, and format.
The string in between the first and second commas (,) is the size.
Specific Example 1
The minimum is 1 and the
maximum is 500, so the
desired value between 1 and
500 is Output Setting: Size.
 In the actual EDS file, the [Params] section comes before the [Connection Manager] section.
Specific Example 2
[Connection Manager]
5-8
[Connection Manager]
Connection1 =
[Params]
Param2 =
Connection1 =
0x04010002,
,100,,
,Param1,,
Output Setting: Size is 100.
0x04010002,
$ trigger & transport
,Param2,,
$ O=>T RPI,Size,Format
,Param1,,
$ T=>O RPI,Size,Format
Output Setting: Size references
Param2.
0,
$ first field shall equal 0
,"",
$ path size, path
0x0000,
$ descriptor
0xC7,
$ data type : UINT
2,
$ data size in bytes
"Output Size",
"BYTE",
$ units
"",
$ help string
1,500,100,
$ min, max, default data values
,,,,
$ mult, dev, base, offset scaling not used
,,,,
$ mult, dev, base, offset link not used
;
$ decimal places not used
$ trigger & transport
$ O=>T RPI,Size,Format
$ T=>O RPI,Size,Format

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

263if-01Japmc-cm2304-e

Table of Contents