6.5.4 Special Functions 14-**

Par.
Parameter description
No. #
14-2* Trip Reset
14-20 Reset Mode
14-21 Automatic Restart Time
14-22 Operation Mode
14-23 Typecode Setting
14-28 Production Settings
14-29 Service Code
14-5* Environment
14-50 RFI Filter
14-53 Fan Monitor
14-54 Bus Partner

6.5.5 FC Information 15-**

Par.
Parameter description
No. #
15-0* Operating Data
15-00 Operating Hours
15-01 Running Hours
15-03 Power Up's
15-04 Over Temp's
15-05 Over Volt's
15-07 Reset Running Hours Counter
15-1* Data Log Settings
15-10 Logging Source
15-11 Logging Interval
15-12 Trigger Event
15-13 Logging Mode
15-14 Samples Before Trigger
15-2* Historic Log
15-20 Historic Log: Event
15-21 Historic Log: Value
15-22 Historic Log: Time
15-3* Fault Log
15-30 Fault Log: Error Code
15-31 Fault Log: Value
15-32 Fault Log: Time
15-4* Unit Identification
15-40 FC Type
15-41 Power Section
15-42 Voltage
15-43 Software Version
15-44 Ordered Typecode String
15-45 Actual Typecode String
15-46 Unit Ordering No
15-47 Power Card Ordering No
15-48 LCP Id No
15-49 SW ID Control Card
15-50 SW ID Power Card
15-51 Unit Serial Number
15-53 Power Card Serial Number
15-6* Option Ident
15-60 Option Mounted
15-61 Option SW Version
15-62 Option Ordering No
15-63 Option Serial No
15-70 Option in Slot A
15-71 Slot A Option SW Version
15-72 Option in Slot B
15-73 Slot B Option SW Version
15-74 Option in Slot C0
15-75 Slot C0 Option SW Version
15-76 Option in Slot C1
15-77 Slot C1 Option SW Version
15-9* Parameter Info
15-92 Defined Parameters
15-93 Modified Parameters
15-98 Unit Identification
15-99 Parameter Metadata
Default value
[0] Manual reset
10 s
[0] Normal operation
null
[0] No action
0 N/A
[1] On
[1] Warning
1 N/A
Default value
4-set-up
0 h
All set-ups
0 h
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
0
2 set-ups
ExpressionLimit
2 set-ups
[0] False
1 set-up
[0] Log always
2 set-ups
50 N/A
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 ms
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 s
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
®
MG.20.T1.02 - VLT
is a registered Danfoss trademark
6 How to Programme the Low Harmonic Drive
4-set-up
FC 302
Change dur-
only
ing opera-
tion
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
TRUE
2 set-ups
TRUE
FC 302
Change dur-
Conver-
only
ing opera-
sion index
tion
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
Conver-
Type
sion index
-
Uint8
0
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Int32
-
Uint8
-
Uint8
0
Uint16
6
Type
74
Uint32
74
Uint32
0
Uint32
0
Uint16
0
Uint16
-
Uint8
-
Uint16
-3
TimD
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint32
-3
Uint32
0
Uint16
0
Int16
0
Uint32
0
VisStr[6]
0
VisStr[20]
0
VisStr[20]
0
VisStr[5]
0
VisStr[40]
0
VisStr[40]
0
VisStr[8]
0
VisStr[8]
0
VisStr[20]
0
VisStr[20]
0
VisStr[20]
0
VisStr[10]
0
VisStr[19]
0
VisStr[30]
0
VisStr[20]
0
VisStr[8]
0
VisStr[18]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
VisStr[30]
0
VisStr[20]
0
Uint16
0
Uint16
0
VisStr[40]
0
Uint16
147