9 Troubleshooting
No.
Description
1
10 Volts low
2
Live zero error
3
No motor
4
Mains phase loss
5
DC link voltage high
6
DC link voltage low
7
DC over voltage
8
DC under voltage
9
Inverter overloaded
10
Motor ETR over temperature
11
Motor thermistor over temperature
12
Torque limit
13
Over Current
14
Earth fault
15
Hardware mismatch
16
Short Circuit
17
Control word timeout
23
Internal Fan Fault
24
External Fan Fault
25
Brake resistor short-circuited
26
Brake resistor power limit
27
Brake chopper short-circuited
28
Brake check
29
Drive over temperature
30
Motor phase U missing
31
Motor phase V missing
32
Motor phase W missing
33
Inrush fault
34
Fieldbus communication fault
35
Out of frequency range
36
Mains failure
37
Phase Imbalance
39
Heatsink sensor
40
Overload of Digital Output Terminal 27
41
Overload of Digital Output Terminal 29
42
Overload of Digital Output On X30/6
9
42
Overload of Digital Output On X30/7
46
Pwr. card supply
47
24 V supply low
48
1.8 V supply low
49
Speed limit
50
AMA calibration failed
51
AMA check U
nom
52
AMA low I
nom
53
AMA motor too big
54
AMA motor too small
55
AMA parameter out of range
56
AMA interrupted by user
57
AMA timeout
58
AMA internal fault
59
Current limit
60
External Interlock
62
Output Frequency at Maximum Limit
64
Voltage Limit
65
Control Board Over-temperature
66
Heat sink Temperature Low
67
Option Configuration has Changed
68
Safe Stop Activated
69
Pwr. Card Temp
70
Illegal FC configuration
71
PTC 1 Safe Stop
72
Dangerous Failure
73
Safe Stop Auto Restart
76
Power Unit Setup
79
Illegal PS config
80
Drive Initialised to Default Value
91
Analog input 54 wrong settings
92
NoFlow
93
Dry Pump
94
End of Curve
95
Broken Belt
96
Start Delayed
97
Stop Delayed
98
Clock Fault
Table 9.1: Alarm/Warning code list
170
and I
nom
MG.20.T1.02 - VLT
VLT AQUA Low Harmonic Drive Operating In-
Warning
Alarm/Trip
Alarm/Trip Lock
X
(X)
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
(X)
(X)
X
X
X
(X)
(X)
X
X
(X)
(X)
X
X
(X)
(X)
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
X
X
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1)
X
X
X
1)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
®
is a registered Danfoss trademark
Parameter Reference
6-01
1-80
(X)
14-12
1-90
1-90
X
X
X
X
8-04
14-53
2-13
2-15
X
(X)
4-58
(X)
4-58
(X)
4-58
X
X
5-00, 5-01
5-00, 5-02
5-32
5-33
X
X
X
X
X
X
X
1)
X
X
22-2*
22-2*
22-5*
22-6*
22-7*
22-7*
0-7*
structions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA and is the answer not in the manual?

Questions and answers

Table of Contents