8

Configuration

Check the protective function before commissioning and after any change!
If you change the configuration, you must check the effectiveness of the protective function. To
this end, note the test instructions in the operating instructions for the connected safety equip-
ment.
Additional information
For configuring the MSI 400 system, you will require the MSI.designer software and the MSI-SD-CARD
program removable storage.
The configuration and verification of devices that are connected to the safety control generally does not
take place using the MSI.designer software. These devices have their own mechanisms for configuration
and verification.
• The system configuration of the entire MSI 400 system is stored in the program removable storage.
This has the advantage that the system does not have to be reconfigured when modules and/or gate-
ways are replaced.
• The data stored in the program removable storage will be retained even if the supply voltage is inter-
rupted.
• It is possible to transfer configuration information via the USB or Ethernet interface.