Tab. 12.3:
Test periods and response times
Test periods for both test outputs (ms)
Test output 1
40
40
200
200
400
400
600
600
800
800
1000
1
Obtain the values from the report in MSI.designer.
Example
The following examples shows the determination of the response time of a safety function (sensor – logical
function – actuator).
Tab. 12.4:
Response time of a safety function
Sub-function
Response time of the sensor
Test time for testable sensors, e.g. Type 2 contact-
less safety devices
With testable sensors, the response time increases
by the active test gap + 12 ms.
Thus, with a test gap of 4 ms, there is an additional
response time of 4 ms + 12 ms = 16 ms
Filter time
When the ON-OFF filter is active, + 8 ms
Standard time
Controller module input to controller module output
With a cycle time of 4 ms.
Logics for switch-off delay times
If function blocks with switch-off delay are used in the
logic plan, then these times have to be added to the
response time.
Actuator response time
Total time
Leuze electronic
1
Test output 2
40
200-1000
200
400-1000
400
600
800-1000
600
800
1000
800
1000
1000
MSI 400
Resulting additional response time (ms)
MSI-EM-IO84 (to B‑07)
MSI 4xx (to D‑01.xx)
20
40
100
200
300
400
400
500
600
700
800
900
Time
+ 18.0 ms
+ 16.0 ms
0.0 ms
+ 11.6 ms
0.0 ms
+ 35.0 ms
80.6 ms
Technical data
MSI-EM-IO84 (from
B‑08)
MSI 4xx (from D‑03.xx)
40
80
200
400
400
600
800
600
800
1000
800
1000
1000
Remarks
Manufacturer informa-
tion
Test generators T1 to
T4
or X1 to X8
MSI.designer
See table: "Standard
time"
MSI.designer
Manufacturer informa-
tion
77