Error No.
Error type Logbook message
2504xxx1
Error
2504xxx2
Error
2504xxx3
Error
2504xxxx
Error
25050001
Info
25050002
Info
25050003
Info
2505xxxx
Info
2509xxxx
Warning
2604xxxx
Warning
2609xxxx
Warning
260Axxxx
Warning
260Bxxxx
Error
2733xxxx
Warning
28020000
Info
2805xxxx
Warning
2808xxxx
Warning
2809xxxx
Warning
280Axxxx
Warning
2B0Exxxx
Warning
2Bxxxxxx
Warning
3409xxxx
Warning
Leuze electronic
Supply voltage A1 too high
Supply voltage B1 too high
Supply voltage B2 too high
Supply voltage too high
Supply voltage A1 within normal
range
Supply voltage B1 within normal
range
Supply voltage B2 within normal
range
Supply voltage within normal
range
External error
Internal/external error SBUS
Error in system configuration.
Error in system configuration.
Too many expansion modules in-
serted
Input discrepancy rectified
Values were changed
Communication interrupted
No SD card
Action not permitted
Ethernet connection too slow
Time for logic processing ex-
ceeded
Internal error
Invalid force request
MSI 400
System behavior
Remedy
System stop;
Supply voltage
voltage OFF-ON re-
must be set cor-
quired
rectly
System stop;
Supply voltage
voltage OFF-ON re-
must be set cor-
quired
rectly
System stop;
Supply voltage
voltage OFF-ON re-
must be set cor-
quired
rectly
System stop;
Supply voltage
voltage OFF-ON re-
must be set cor-
quired
rectly
System continues
-
to run
System continues
-
to run
System continues
-
to run
System continues
-
to run
System continues
Check load current
to run
System continues
Reduce the number
to run
of expansion mod-
ules
System continues
Reload system con-
to run
figuration
System continues
Reload system con-
to run
figuration
System stop;
Check connection
voltage OFF-ON re-
of modules
quired
System continues
-
to run
System continues
-
to run
System stop
Repeat action
Configuration re-
Insert SD card
quired
System continues
Execute correct ac-
to run
tion
System continues
-
to run
System continues
-
to run
System continues
-
to run
System continues
-
to run