Error No.
Error type Logbook message
243CFx0C Warning
243CFx0D Warning
243CFx0E Warning
243CFx0F Warning
243CFx10
Warning
243CFx11
Warning
243CFx12
Warning
243CFx13
Warning
243CFxxx
Warning
243D0012
Warning
243D0034
Warning
25010001
Warning
25010002
Warning
25010003
Warning
2501xxxx
Warning
25020001
Warning
25020002
Warning
25020003
Warning
2502xxxx
Warning
2503xxx1
Error
Leuze electronic
Stuck-at-high safety mat at I13
Stuck-at-high safety mat at I14
Stuck-at-high safety mat at I15
Stuck-at-high safety mat at I16
Stuck-at-high safety mat at IQ1
Stuck-at-high safety mat at IQ2
Stuck-at-high safety mat at IQ3
Stuck-at-high safety mat at IQ4
Stuck-at-high safety mat
Error in system configuration
Error in system configuration
Supply voltage A1 too low
Supply voltage B1 too low
Supply voltage B2 too low
Supply voltage too low
Supply voltage A1 too high
Supply voltage B1 too high
Supply voltage B2 too high
Supply voltage too high
Supply voltage A1 too low
MSI 400
System behavior
Remedy
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
System continues
Check cabling
to run
Configuration re-
Reload system con-
quired
figuration
Configuration re-
Reload system con-
quired
figuration
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System continues
Supply voltage
to run
must be set cor-
rectly
System stop;
Supply voltage
voltage OFF-ON re-
must be set cor-
quired
rectly
Appendix