Leuze electronic MSI 400 Operating Instructions Manual page 21

Integrating safety sensors
Hide thumbs Also See for MSI 400:
Table of Contents

Advertisement

Pin
assignment
IQ1 - IQ4
Safe, digital inputs or outputs (configurable through MSI.designer)
B1
24 V supply voltage of outputs Q1 - Q4
B2
24 V supply voltage of configurable outputs IQ1 - IQ4
T1 - T4
Test signal outputs
USB interface
The controller module has a mini-USB interface with the following functions:
• Transfer of the configuration from MSI.designer to the program removable storage
• Reading of configuration from program removable storage in MSI.designer
• Diagnostics of the MSI 400 system with MSI.designer
Tab. 3.8:
USB interface pin assignment
Connector/
bushing
USB
NOTICE
Ä If the USB interface of the controller module is permanently connected, then the maximum
i
permissible cable length is 3 m.
Ä Avoid using ground loops between the USB interface GND and the A2 connection of the
controller module, e.g. by using optocouplers.
Ethernet interface
The controller module has an Ethernet interface with the following functions:
• Transfer of the configuration from MSI.designer to the program removable storage
• Reading of configuration from program removable storage in MSI.designer
• Diagnostics of the MSI 400 system with MSI.designer
• Continuous diagnostics of the MSI 400 system via a connected PLC
Tab. 3.9:
RJ 45 bushing pin assignment
Connector/bushing
RJ45
The device itself detects which cable type, patch cable or cross-link cable, is being used (Auto MDI-X),
which is why the pin assignment does not matter with regard to the RD or TD signals.
Leuze electronic
Pin
Signal
1
+5V
2
- data
3
+ data
5
GND
Pin
Signal (Auto MDI-X)
1
RD+ / TD+
2
RD- / TD-
3
TD+ / RD+
6
TD- / RD-
MSI 400
Product description
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents