Leuze electronic MSI 400 Operating Instructions Manual page 56

Integrating safety sensors
Hide thumbs Also See for MSI 400:
Table of Contents

Advertisement

Step 1: Installing a controller module
Ä Using a screwdriver, pull the snap-on foot outward.
Ä Hang the module on the hat rail.
Important! Make sure that the shielding spring fits correctly.
The shielding spring of the module must be placed onto the hat rail so that it is secure and has good
electrical contact.
Ä Fold the module onto the hat rail.
Ä Using a screwdriver, move the snap-on foot against the hat rail until the snap-on foot latches into posi-
tion with an audible click.
Ä Make sure that the module is securely seated on the hat rail.
Attempt to pull the module from the hat rail using slight pressure. If the module stays connected to the
hat rail during this test, then the installation is correct.
Leuze electronic
MSI 400
Installing/removing
56