Installation Requirements And Configurations - ClipperCreek ProMountDuo PMD-10T Installation Manual

Pedestal
Table of Contents

Advertisement

INSTALLATION REQUIREMENTS AND CONFIGURATIONS

(continued)
CONFIGURATION H:
Required Equipment for a Combo Dual-Mount Pedestal with one HCS EVSE
and one TESLA
EVSE (Two EVSE per Pedestal):
®
One (1) ClipperCreek ProMountDuo™ Kit, ClipperCreek part number
0300-00-025.
One (1) ClipperCreek HCS EVSE, part number is determined by amperage and
options selected.
One (1) TESLA
®
Two (2) dedicated branch circuits, voltages dependent upon the EVSE options
selected.*
Two (2) circuit breakers, appropriately sized with respect to the charging
capacity of each EVSE.*
Appropriately sized service wiring based on EVSE power requirements
(reference EVSE Product manual). Each conductor must have enough length
to comfortably pull all the way through and above the top of the pedestal
(5 feet is adequate).
Two (2) Ground Line conductors (one for each EVSE) or a single bonded
Ground Line with enough length to comfortably pull all the way through and
above the top of the pedestal (5 feet is adequate).
Conduit sized to fit all conductors.
Four (4) Anchor Bolts with Nuts and Washers (additional washers may be
required for leveling)
CONFIGURATION I:
Required Equipment for a Combo Dual-Mount Pedestal with one
ClipperCreek LCS/ACS and one TESLA
One (1) ClipperCreek ProMountDuo™ Kit, ClipperCreek part number
0300-00-025.
One (1) ClipperCreek LCS/ACS EVSE part number is determined by
amperage and options selected.
One (1) TESLA
®
Two (2) dedicated branch circuits, voltages dependent upon the EVSE option
selected.*
Two (2) circuit breakers, appropriately sized with respect to the charging
capacity of each EVSE.*
Appropriately sized service wiring based on EVSE power requirements
(reference EVSE Product manual). Each conductor must have enough length to
comfortably pull all the way through and above the top of the pedestal (5 feet is
adequate).
Two (2) Ground Line conductors (one for each EVSE) or a single bonded
Ground Line with enough length to comfortably pull all the way through and
above the top of the pedestal (5 feet is adequate).
Conduit sized to fit all conductors.
Four (4) Anchor Bolts with Nuts and Washers (additional washers may be
required for leveling).
ProMountDuo™ PEDESTAL INSTALLATION GUIDE
EVSE, TESLA
part number 1050067-01-E.
®
EVSE, TESLA
part number 1050067-01-E.
®
* Consult the TESLA
EVSE (Two EVSE per Pedestal):
®
Wall Connector Manual if selecting the TESLA
®
Page 15
ClipperCreek
CONFIGURATION H
Combo TESLA
EVSE
®
and ClipperCreek
HCS EVSE
CONFIGURATION I
Combo TESLA
EVSE
®
and ClipperCreek
LCS/ACS EVSE
Load Sharing Option.
®
, Inc.