Installation - Service Wiring; Delta Service Connections - ClipperCreek CS 3-Phase Installation Manual

Table of Contents

Advertisement

CS 3-Phase Installation Manual

INSTALLATION - SERVICE WIRING

Delta Service Connections

NOTE:
Motiv drivetrain vehicles cannot use a Delta Service
Connection.
This EVSE is configured for use with 3-phase AC power. Either
Delta or Wye service connections can be used in most cases; the
exception is that Motiv drivetrain vehicles will have to use a WYE
supply transformer. Delta-feed service connections to the EVSE
must be made in a specific manner, adhering to the following
requirements:
1. One winding MUST BE CENTER TAPPED. This
center tap must be connected to EARTH GROUND at
some point in the system.
2. LINE 1 and LINE 2 must be drawn from the phases at
each end of the center-tapped winding. This provides
120VAC to EARTH GROUND for both LINE 1 and
LINE 2.
3. LINE 3 is drawn from the 208VAC "Stinger" phase.
See Figure 4.
Figure 4. Delta Service Connections
use a Delta Service Connection)
(Motiv drivetrain vehicles cannot
Page 14