106
Syntax
SetCheckModeAfterRead = 0 | 1
Example
SetCheckModeAfterRead = 0
5.10.1.12SetResetPulseLen
This command defines the length of the RESET pulse in milliseconds. The default for
the RESET pulse length is 20 milliseconds.
Syntax
SetResetPulseLen = <value>
Example
SetResetPulseLen = 50
5.10.1.13SetResetType
This command changes the reset strategy.
Typical applications
Refer to chapter Reset strategies on page 98 for additional informations about the
different reset strategies.
Value
0
1
2
Table 5.11: List of possible value for command SetResetType
Syntax
SetResetType = <value>
Example
SetResetType = 0
5.10.1.14SetRestartOnClose
This command specifies whether the J-Link restarts target execution on close. The
default is to restart target execution. This can be disabled by using this command.
Syntax
SetRestartOnClose = 0 | 1
Example
SetRestartOnClose = 1
5.10.1.15SetDbgPowerDownOnClose
When using this command, the debug unit of the target CPU is powered-down when
the debug session is closed.
Note:
This command works only for Cortex-M3 devices
J-Link / J-Trace (UM08001)
CHAPTER 5
Hardware, halt after reset (normal).
Hardware, halt with BP@0.
Software, for Analog Devices ADuC7xxx MCUs.
© 2004-2009 SEGGER Microcontroller GmbH & Co. KG
Working with J-Link and J-Trace
Description
Need help?
Do you have a question about the J-Link and is the answer not in the manual?
Questions and answers