7. Record the location of where each wire connects
to the Control Board. You will have to reattach each
wire to the new Control Board.
8. Disconnect the Tach Cable noting the location.
9. Disconnect the AC Power Wire Plug noting the
location.
AC Power Wire Plug
10. Disconnect the I/O Cable from the Motor Control
Board.
11. Disconnect the Motor Power Wires noting their
location.
I/O Cable
12. Using a #2 Phillips screwdriver, remove the two
screws from the Motor Control Board.
Grounding Wire
13. Remove the Motor Control Board and replace.
14. Secure the new Motor Control Board with the
hardware.
15. Connect the Tach Cable and the I/O Cable.
I/O Cable
16. Connect Motor Power Wires. NOTE: Red wire
connects to terminal labeled "M+RED". Black wire
Tach Cable
connects to terminal labeled "M-BLK".
Motor Power Wires
17. Connect the A/C Power Wire Plug to the Motor
Control Board.
18. Replace the Motor Compartment Cover, the
Rear Cover, and the Rear Step.