7. Troubleshooting
If the condition does not change after performing the countermeasure, the unit may have
suffered a breakdown.
Please contact the service center or the manufacturer.
Display panel is blank
- The Controller supplies 24VDC.
Check that the Controller is ON.
- Check that the Controller is connected to the TP port of the Controller properly.
An Error code appears and the Robot does not operate normally
- Please refer to the error code in the following manual.
Robot does not move by pressing the Jog key
- Execute the Motor On command to energize the Robot motor.
For details, refer to the following manual:
- Energize the Robot motor.
For details, refer to the following manual:
- Short jog distance may be selected.
Check the value in the [Jog Distance] and change the setting to long distance if needed.
For details, refer to the following section:
Operation mode does not switch from TEACH mode to AUTO mode
- Turn ON the latch release input of the EMERGENCY connector to release the latch
status.
Program list is not displayed in program verification window of TEST
mode
- Check for the setting whether it is set to store execution source files to the Controller.
Settings can be confirmed by following steps:
Select EPSON RC+ menu- [Project]-[Properties]-[Source Files In Controller] and check if
desired files are checked in [Select source files to store in controller:].