Restore - Epson TP3 Manual

Robot controller rc700-a option teach pendant
Table of Contents

Advertisement

Operation 5. AUTO Mode

5.2.2 Restore

This panel is used for restoring the Robot system configuration from the backup data
saved in the USB memory. The Robot system cannot be restored while the task is being
executed.
To restore the Robot system configuration:
(1) Insert the USB memory which contains the data to the Teach Pendant.
(2) Tap the <Restore> button.
(3) Select the data you want to restore from the [Browse for folder] panel.
(4) Tap the <OK> button.
(5) Check the information to restore in the [Restore Controller] panel.
(6) Tap the <OK> button.
If the current Controller configuration and that of the backup data differ, a warning
message will appear. Restoration must be performed on the same system.
The Robot system restarts after restoring the data.
To remove the USB memory:
Tapping the <Unmount> button displays the removal instruction. Remove the USB
memory by following the instruction.
For details of cautions for using the USB memory, refer to Operation 8. USB Port.
78
The [Browse for folder] panel will appear.
The [Browse for folder] panel closes and the [Restore Controller] panel will appear.
The data restoration will start.
RC700-A option TP3 Rev.8

Advertisement

Table of Contents
loading

Table of Contents