A. Technical data and accessories
A.1
Technical data
General information
Temperature range:
– Operation
– Storage/transport
Relative air humidity
Recommended shelf life
Protection class
Protection against electric shock
(protection against direct and indirect contact
as per EN 60204-1/IEC 204)
Valves
Operating voltage of electronics
Pin 1 of power supply connection
– Nominal value
– Tolerance
Current consumption
– Nominal value
Residual ripple
Festo P.BE-CDVI-DN-EN en 0805a
- 5°C ... + 50°C
-20°C ... + 40°C
95 %, non condensing
Max. 18 months
– IP66 and IP67 (EN 60529)
– Type 4 as per NEMA250
(hosedown test, test no. 5.7)
By means of PELV power supply unit
(protected extra low voltage)
See description of pneumatics type P.BE-CDVI-...
24 V DC (protected against incorrect polarity, inter-
nally fused, automatic restart, galvanically isolated
from the power supply of the valves, provided PIN3
and PIN4 are not bridged, see page 1-21)
20.4 ... 26.4 V (- 15% / + 10%)
Max. 100 mA + current consumption of sensors
(and modules; see section 1.4.1)
4 Vpp (within tolerance)
A-3