1. Installation

1.4.2 Selecting the cables

1.4.3 Selecting the power supply unit

Festo P.BE-CDVI-DN-EN en 0805a
Calculate the required cable cross section and the maxi-
mum permitted line length.
Avoid long distances between the power supply unit
and the valve terminal. Long cables reduce the voltage
supplied by the power supply unit.
Make sure the cables and sockets meet the ambient condi-
tions (e.g. cleaning agents used) and fulfil the requirements
of IP protection class.
Warning
Use only PELV circuits as per IEC/DIN EN 60204-1 for
the electric power supply (protective extra-low voltage,
PELV).
Also observe the general requirements for PELV circuits
laid down in IEC/DIN EN 60204-1.
Use only power sources that guarantee reliable
electrical isolation of the operating voltage as per
IEC/DIN EN 60204-1.
Protection against electric shock (protection against
direct and indirect contact) is guaranteed in accordance
with IEC/DIN EN 60204-1 by using PELV circuits (electrical
equipment of machines, general requirements).
Recommendation:
Use controlled power supply units.
Before selecting the power supply units, calculate
the total current requirement in accordance with
section 1.4.1.
1-21