Festo CDVI-DN Manual page 68

Valve terminal with direct fieldbus connection, (type 15), devicenet
Hide thumbs Also See for CDVI-DN:
Table of Contents

Advertisement

2. Startup
2-24
The following table shows an example of with which bit you
can address the valve coils:
Address
Unit
0
1
2
3
4
5
6
7
Word
8
9
10
11
12
13
14
15
16
17
18
19
Byte
20
21
22
23
Tab. 2/4: Assignment of the bits to the solenoid coils
Bit
Assigned valve
0
1st valve/coil 14
1
1st valve/coil 12
2
2nd valve/coil 14
3
2nd valve/coil 12
4
3rd valve/coil 14
5
3rd valve/coil 12
6
4th valve/coil 14
7
4th valve/coil 12
8
5th valve/coil 14
9
5th valve/coil 12
10
6th valve/coil 14
11
6th valve/coil 12
12
7th valve/coil 14
13
7th valve/coil 12
14
8th valve/coil 14
15
8th valve/coil 12
0
9th valve/coil 14
1
9th valve/coil 12
2
10th valve/coil 14
3
10th valve/coil 12
4
11th valve/coil 14
5
11th valve/coil 12
6
12th valve/coil 14
7
12th valve/coil 12
Festo P.BE-CDVI-DN-EN en 0805a