Festo CDVI-DN Manual page 43

Valve terminal with direct fieldbus connection, (type 15), devicenet
Hide thumbs Also See for CDVI-DN:
Table of Contents

Advertisement

1. Installation
Festo P.BE-CDVI-DN-EN en 0805a
CP output module with 8 outputs. Power supply of the
electronics via the CP extension connection. Load voltage:
separately via an M18 plug.
CP output module with 4 outputs. Power supply of the
electronics and load via the CP string.
CPV valve terminals with widths of 10, 14 and 18 mm.
Available with 4, 6 or 8 valve sub-bases.
CPV valve terminals with widths of 10 and 14 mm.
Available with max. 8 valve sub-bases (each with 2 coils)
or with max. 16 valve sub-bases (each with 1 coil).
Note
The CDVI-DN can be extended by no more than:
– One CP input module and
– One CP valve terminal or one CP output module.
Caution
Data transmission faults if the maximum permitted signal
line length is exceeded
The total signal line length between the CDVI-DN and the
last CP module must not exceed 10 m.
The CP connecting cables must have special electrical
properties. Therefore make sure you use Festo CP connect-
ing cables.
Pre-assembled CP connecting cables are available from Festo.
They are available in various lengths and designs. An over-
view can be found in Appendix A.
Note
Use blanking plugs to seal unused connections (import-
ant for protection class IP).
Possible extensions are illustrated in the following diagram: