Security Escort
Element
Guard tour level
Guard tour minutes
Watchdog minutes
9.4

System Defaults

This dialog allows the names for each class of subscribers to be changed to match the specific
application of this Security Escort system.
Robert Bosch (SEA) Pte Ltd
Troubleshooting coordinators, points and receivers | en 111
Usage/Description
This field is the minimum receive level (1-255) that must be heard
before the system will accept a test generated by the guard's
transmitter to be entered as a location in the guard tour report. It
determines the distance the guard's transmitter must be within
from a SE receiver before the system will recognize the test and
create the guard tour entry. If the guard is too far away from the SE
receiver, that SE receiver's green light will not be displayed, so the
guard knows that they must move closer to the SE receiver for the
test to register.
This field controls the time spacing, in minutes, for entries of the
guard's current location in the automatically generated guard tour
report. Therefore, if set to 15 minutes, an entry will be generated
each 15 minutes that the guard's transmitter is within range of the
system.
This field controls the time spacing, in minutes, for entries of the
guard's current location in the automatically generated guard tour
report. Therefore, if set to 10 minutes, an entry will be generated
each 10 minutes that the guard's transmitter is within range of the
system.