Security Escort
Elements
Pager ID
Pager Groups
Pager
Confirmation Not
Required
Fixed location
transmitter
Robert Bosch (SEA) Pte Ltd
Troubleshooting coordinators, points and receivers | en 121
Usage/Description
This is the ID that identifies the pager to receive the pager message
(many times this value is the last 7 digits that would be manually dialed
to access this pager). The pager ID is assigned by the paging service.
The first pager group (*) can be used for email notification. You can enter
the email notification group "01", "02", "03" or "04" to configure the
notification of this specific subscriber alarm to be sent via email to that
email notification group. If the pager group (*) is left empty, alarms for
this subscriber will send an email to the default notification group "00".
Any data entered from 5 to 99 in the first pager group (*) will be treated
as a pager group. The subscriber can be a member of up to 3 different
pager groups. Enter the group numbers in the pager group fields
respectively.
If checkbox is selected, the confirmation pager message is not sent to
this pager if alarm is acknowledged by an acknowledgement transmitter.
This section is to be used only when this transmitter is mounted in a
fixed location (does not move). When this transmitter transmits an alarm,
it will always be reported at the programmed location.
Floor level
This is the floor level where this alarm is to be located
for a fixed location transmitter.
Map X
This is the X coordinate of the map position where this
Position
alarm is to be located for a fixed location transmitter.
Map Y
This is the Y coordinate of the map position where this
Position
alarm is to be located for a fixed location transmitter.
[Locate]
When clicked, the dialog will disappear and the cursor
will change to a cross hair. Moving the cursor to a point
on the map and clicking the left mouse button will scroll
the map so that point is at the center of the screen.
When the map is showing the desired alarm location,
move the cross hair to the exact location of the alarm to
be reported and click the right mouse button. The dialog
will reappear and the selected location will be entered
into the X and Y coordinates.
If while the cross hair cursor is being displayed, you
desire to exit without changing any coordinate values,
press the <Esc> key and the transponder edit dialog will
reappear.
Map number
Defines which bitmap is to be displayed for the fixed
location of this transmitter. The default map is 0, which
corresponds to bitmap MAP0.EDB stored in the "Escort"
sub-directory. Map 1 would be MAP1.EDB. There can be
100 maps per Security Escort system, therefore the valid
values are numeric from 0 to 99.