122 en | Troubleshooting coordinators, points and receivers
Elements
Enable reed
switch
Optional text
Disable on
shorted loop
Alarm on shorted
loop
Trouble on
shorted loop
Alarm when
armed, Trouble
when disarmed
on shorted loop
Disable open
loop
Alarm on open
loop
Trouble on open
loop
2018.03 | SE3v1.0 | DOC
Usage/Description
If selected, the reed switch input of this transmitter is enabled to cause
an alarm. Otherwise, the reed switch input will be disabled. The alarm
group, where this transmitter is assigned to, must be armed in order for
this input to cause an alarm (which is displayed). If no alarm group is
assigned, the transmitter is always armed. For this option to be enabled,
the transmitter's class must be set as "Point type".
This is optional text that will be added to the location text when this
input reports an alarm. For this option to be enabled, the transmitter's
class must be set to "Point type".
If selected, a shorted loop on this transmitter will not cause an alarm or
trouble report to be displayed. For this option to be enabled, the
transmitter's class must be set to "Point type".
If selected and the alarm group, where this transmitter is assigned to, is
armed, then a shorted loop on this transmitter will cause an alarm report
to be displayed. The alarm group this transmitter is assigned to must be
armed, for this input to cause an alarm, which is displayed. If no alarm
group is assigned, the transmitter is always armed. For this option to be
enabled, the transmitter's class must be set to "Point type".
If selected, a shorted loop on this transmitter will cause a trouble report
to be displayed. For this option to be enabled, the transmitter's class
must be set to "Point type".
If selected and the alarm group, where this transmitter is assigned to, is
armed; then a shorted loop on this transmitter will cause an alarm report
to be displayed. If selected and the alarm group, where this transmitter
is assigned to, is disarmed, then a shorted loop on this transmitter will
cause a trouble report to be displayed. If no alarm group is assigned, the
transmitter is always armed. For this option to be enabled, the
transmitter's class must be set to "Point type".
If selected, an open loop on this transmitter will not cause an alarm or
trouble report to be displayed. For this option to be enabled, the
transmitter's class must be set to "Point type".
If selected and the alarm group, where this transmitter is assigned to, is
armed, then an open loop on this transmitter will cause an alarm report
to be displayed. The alarm group, where this transmitter is assigned to,
must be armed for this input to cause an alarm, which is displayed. If no
alarm group is assigned, the transmitter is always armed. For this option
to be enabled, the transmitter's class must be set to "Point type".
If selected, an open loop on this transmitter will cause a trouble report
to be displayed. For this option to be enabled, the transmitter's class
must be set to "Point type".