Bosch SE3000 Series Technical Reference Manual page 196

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

196 en | System menus and dialogs
Figure 10.22: Transponder parameter change dialog
Element
Run silent
Optional parameter 2
Disable RS485
Disable Tamper
Disable RF
Optional Parameter 6
Comm fail to siren out
Verbose point reports
2018.03 | SE3v1.0 | DOC
Usage/Description
If selected, the SE receivers on this SE coordinator bus do
not sound an alarm. This includes alarms received during a
communications failure with the Central Console.
This option is currently disabled and reserved for future
use.
If selected, the RS485 bus on this SE coordinator is
disabled.
If selected, the tamper on this SE coordinator is disabled.
If selected, the radio frequency (RF) functionality on this SE
coordinator is disabled.
This option is currently disabled and reserved for future
use.
If this item is selected, the siren output on this SE
coordinator activates when a communications failure is
detected at the Central Console.
If selected, alarm and test reports include average levels
and packet count information. This extra information is for
diagnostic proposes only and is not required for system
operation. Since the additional data increases the system
traffic load leave this item unselected.