Bosch SE3000 Series Technical Reference Manual page 18

Security escort
Hide thumbs Also See for SE3000 Series:
Table of Contents

Advertisement

18
en | System components and specifications
Auto-tracking feature
During an alarm, the SE transmitter automatically resends the alarm signal every few seconds
constantly updating the Central Console of the user's location.
Supervision tracking
With "Supervision Tracking" enabled, the SE transmitter will send a tracking signal to the
Central Console constantly updating the user's location.
Testing
The "Test" mode allows users to test their SE transmitter anywhere in the protected area.
When the user is located indoors in sight of an indoor SE receiver, or outdoors in sight of a
strobe wired to the output of an outdoor SE receiver, pressing the manual test button
performs a test. If the test is successful, a small green light will flash on the indoor SE
receiver, or the strobe will flash briefly. There will be no response at all if the test fails. If the
test fails, the user should contact the Security Office as soon as possible.
When the SE transmitter is tested, a special "low battery" message is included in the
transmission to Central Console if the SE transmitter's battery is in need of replacing. Every
successful test is recorded in the Subscriber Database in the Central Console Software and
optionally printed on the hardcopy printer. The Subscriber Database contains all of the
information related to each subscriber, including the date and time of the most recent test
transmission. It is possible to search the Subscriber Database for individuals who have not
performed tests for a specified period of time.
Temperature Range
Battery
Communication Interface
Frequency
Notice!
The SE personnel transmitter is only compatible with other equipment using the same radio
frequency band.
2018.03 | SE3v1.0 | DOC
Lanyard Pull: A cord connected to the pin, inserted in the base of the SE transmitter can
be looped around a utility belt. If the pin is removed from the SE transmitter (such as
when the SE transmitter is pulled away from the belt), the SE transmitter will
immediately go into alarm.
Technical Reference Manual
-20°C to 65°C (-4°F to 149°F)
3V Lithium CR2 or equivalent
Wireless radio frequency (SE coordinator/SE receiver)
433.42 MHz
Security Escort
Robert Bosch (SEA) Pte Ltd