Security Escort
Element
Select destination group
History screen
Printer
History archive file A
History archive file B
System serial port 1
System serial port 2
Transponder restriction group
No restriction
Only from transponder
selected
All from transponder
selected
Check to output the event group
Alarms
Points, reporting alarm Outputs the SE coordinator and SE receiver levels for an alarm.
Tests, single line
Tests including point
Info
Robert Bosch (SEA) Pte Ltd
Usage/Description
This option selects the events to be displayed on the computer
screen when Show history is selected.
This option selects the events to be sent to the printer.
This option selects the events to be sent to the "a_audit.txt" file
stored in the Security Escort sub-directory (typically "C:
\ESCORT"). There is a minimum set of events that cannot be
disabled, so they are always recorded.
This option selects the events to be sent to the "b_audit.txt" file
stored in the Security Escort sub-directory (typically "C:
\ESCORT").
This option selects the events to be sent to the system serial port
1. System serial port 1 is assigned a physical comm port in the
Remote Comm Port Setup dialog, and the History Filter Output
field must be set in the Remote Setup dialog.
This option selects the events to be sent to the system serial port
2. System serial port 2 is assigned a physical comm port in the
Remote Comm Port Setup dialog, and the History Filter Output
field must be set in the Remote Setup dialog.
This selection is typically left at this setting at all times. The output
is not restricted by an individual SE coordinator.
The selected events are only output if they were reported from the
SE coordinator selected in the drop-down list box above.
All events are reported from the SE coordinator selected above.
The selected events are reported from all other SE coordinators in
the system.
Outputs the information about an alarm including location, but not
the SE coordinator and SE receiver levels. This is the data typically
sent to a printer.
Typically, this is the data too detailed to send to a printer and is
used for diagnostics, not normal system operation.
Outputs the simple information about a test. Typically, this is the
data normally sent to a printer.
Outputs the SE coordinator and SE receiver levels for a test. This is
the data usually too detailed to send to a printer and is used for
diagnostics, not normal system operation. If this option is selected,
Test, single line option would not be selected for the same output
device.
Technical Reference Manual
System menus and dialogs | en 181
2018.03 | SE3v1.0 | DOC