Security Escort
Element
Remote Control
Listening Port
Master Database
path
Autobackup to the
slave database
Slave Database path The path that this master or workstation computer uses to access the
Local Escort path
Other Backup/
Restore path
Subscriber image
file path
Extension
Robert Bosch (SEA) Pte Ltd
Usage/Description
The Security Escort will be listening on this port to communicate with
the OPC server. A separate OPC server is created to communicate
between the OPC client and the Security Escort system. The OPC
server holds the alarm and trouble messages, and sends the same to
the available client once it is connected. The OPC server will send the
status of the Security Escort to the OPC client. The OPC sever also
acknowledges and deletes alarm and trouble messages from OPC
client. If the connection between OPC server and Security Escort goes
down, the OPC server will try to reconnect with Security Escort. Once
the connection to the Security Escort becomes active, the Security
Escort will send all the available alarms to the OPC server. The OPC
server in turn sends the alarm back to OPC client; hence the OPC
client may display some duplicate alarms.
The path that this slave or workstation computer uses to access the
shared database files on the master computer. This path may have a
different drive letter on the different slave and workstation
computers. They are typically on the master computer, but they may
be on a file server or any other network accessible drive.
If this option is selected, the slave computer will back up all
databases in the Master Database path to the Slave Database path
each night at 3:00 am.
hot backup database files on the slave computer. This path may have
a different drive letter on the different master and workstation
computers. They are usually on the slave computer, but they may be
on a file server or any other network accessible drive. Typically, they
would not be stored on the same computer as the Master Database
path, so a single failure would not prevent access to both the master
and slave database files.
The path on this workstation where the Security Escort was installed
in. Typically it is "C:\ESCORT".
When backing up the database to or restoring it from external disks,
this is the path that is used.
The Security Escort System software can display an image for each
subscriber on the alarm screen. This parameter tells the software the
path where the image files are stored. The default is "C:\ESCORT
\IMAGES".
The subscriber images can be in JPEG or Windows Bitmap format. All
images in a system must be in the same format. For the JPEG format,
enter the Windows extension "JPG". For the Bitmap format, enter the
Windows extension "BMP".
Technical Reference Manual
System menus and dialogs | en 219
2018.03 | SE3v1.0 | DOC