RealPresence Collaboration Server (RMX) 2000 Components and Components Replacement
Replace the CNTL Module
The CPU module is the management system of the RealPresence Collaboration Server (RMX) 2000. Use
the following procedure to replace a CNTL Module.
To replace the CNTL module:
1 Ensure that power switch on the RMX 2000 is turned OFF (O).
2 Unscrew the captive screws on the front panel of the RMX 2000 that secure the CNTL Module.
3 Use the metal ejector lever to pull the CNTL Module out of its slot in the Backplane.
4 Carefully slide the CNTL Module out through the front panel.
.
5 On the CNTL Module to be installed, move the ejector lever to the fully open position.
6 Slide in the replacement CNTL Module.
7 Push the CNTL Module firmly into the Backplane, making sure it is properly seated in its slot.
8 Ensure that the metal ejector lever is fully retracted into its housing.
9 Tighten the captive screws on the front panel of the RMX 2000 to secure the Functional CNTL
Module.
10 Turn ON the RMX 2000.