RealPresence Collaboration Server (RMX) 2000 Components and Components Replacement
Replace the Fan Drawer
Three fans are mounted in the Fan drawer, where the airflow is from right to left. Should one of these fans
fail as indicated by a Fan LED, you are required to replace the Fan drawer.
To replace the Fan Drawer:
1 Unscrew the captive screws on the front panel of the RealPresence Collaboration Server (RMX)
2000 to secure the Fan drawer.
2 Use the metal ejector levers to pull the Fan drawer out of its slot in the Backplane.
3 Carefully slide the Fan drawer out through the front panel.
.
Caution: Fan drawer replacement must be done immediately
The Fan drawer can be replaced when the RealPresence Collaboration Server (RMX) 2000 unit is
ON, however a replacement drawer must be inserted immediately. The temperature increase is
detected by the system; when critical, a system shutdown is initiated.
4 Slide in the replacement Fan drawer.
5 Push the Fan drawer firmly into the Backplane, making sure it is properly seated in its slot.
6 Tighten the captive screws on the front panel of the RMX 2000 that secure the Fan drawer.
Polycom, Inc.
53