RealPresence Collaboration Server (RMX) 4000 Components and Components Replacement
Replace the CNTL 4000 Module
The CPU module is the management system of the RMX 4000. Use the following procedure to replace a
CNTL 4000 Module.
To replace the CNTL 4000 module:
1 Ensure that the power switch/circuit switch on the RMX 4000 is turned OFF (O).
2 Unscrew the captive screws on the front panel of the CNTL 4000 Module that secure the module to
the chassis.
3 Use the metal ejector lever to pull the CNTL 4000 Module out of its slot in the Backplane.
4 Carefully slide the CNTL 4000 Module out through the front panel.
5 On the CNTL 4000 Module to be installed, move the ejector lever to the fully open position.
6 Slide in the replacement CNTL 4000 Module.
7 Push the CNTL 4000 Module firmly into the Backplane, making sure it is properly seated in its slot.
8 Ensure that the metal ejector lever is fully retracted into its housing.
9 Tighten the captive screws on the front panel of the CNTL
chassis.
10 Turn ON the RMX 4000.
Polycom, Inc.
4000
Module to secure the module to the
64