Technical data
12.8 Electromagnetic Compatibility
Table 12- 7
EMC Phenomenon
Conducted emissions
(disturbance voltage)
Radiated emissions
Harmonic Currents
Table 12- 8
Typical Harmonic Current (% of rated input current) at U
Note
Units installed within the category C2 (domestic) environment require supply authority
acceptance for connection to the public low-voltage power supply network. Please contact
your local supply network provider.
Units installed within the category C3 (industrial) environment do not require connection
approval.
262
Conducted disturbance voltage and radiated emissions
Converter type
Remark
All converters with integrated class A filters.
Order number:
6SL3525-0PE**-*A**
Converter frame sizes A, B and C with integrated
class A filter.
Order number:
6SL3525-0PE17-*A**
6SL3525-0PE21-*A**
6SL3525-0PE23-*A**
6SL3525-0PE24-*A**
6SL3525-0PE25-*A**
6SL3525-0PE27-*A**
In a domestic environment this product may cause
radio interference in which case supplementary
mitigation measures may be required.
Harmonic Currents
5th
7th
54
39
11th
13th
11
5
Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA
1 %
K
17th
19th
5
3
Converter with control units CU240D-2
Level acc. to
IEC 61800-3
Category C2
First Environment -
Professional Use
Category C2
First Environment -
Professional Use
23rd
25th
2
2