Siemens SINAMICS G120D Operating Instructions Manual page 119

Control units, distrubuted converter
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

2. Binary selection:
Parameter for setting the fixed setpoints
Parameter
p1001
p1002
...
p1015
p1016
p1020
p1021
p1022
p1023
r1024
r1025.0
Converter with control units CU240D-2
Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA
Additional information about direct selection can be found in function diagram 3011 in the
List Manual.
You set 16 different fixed setpoints. You precisely select one of these 16 fixed setpoints
by a combination of four selection bits.
Additional information about binary selection can be found in function diagram 3010 in the
List Manual.
Description
Fixed speed setpoint 1 (factory setting: 0 rpm)
Fixed speed setpoint 2 (factory setting: 0 rpm)
...
Fixed speed setpoint 15 (factory setting: 0 rpm)
Fixed speed setpoint mode (factory setting: 1)
1:
2:
Fixed speed setpoint selection bit 0 (factory setting: 0)
Fixed speed setpoint selection bit 1 (factory setting: 0)
Fixed speed setpoint selection bit 2 (factory setting: 0)
Fixed speed setpoint selection bit 3 (factory setting: 0)
Fixed speed setpoint effective
Fixed speed setpoint status
1 signal
Direct
Binary
Fixed speed setpoint is selected
Setting functions
8.3 Setpoints
119

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu240d-2

Table of Contents