12.4 Err 01-24 (not possible to start upper fan)

Description The control board A1 does not receive any response regarding speed
Troubleshooting

12.5 Err 01-25 (not possible to start lower fan)

Description The control board A1 does not receive any response regarding speed
Troubleshooting

12.6 Err 06-13 (emergency rinse not possible)

Description This fault message appears if the automatic rinse is not possible after
Troubleshooting After the fault message has been acknowledged, additional
Switch unit on "I."
Check the output voltage at connector X2 between terminals 1
and 2.
No voltage present. Replace power board for motor.
Voltage present. Replace fan motor.
from upper fan motor M10. There is either a problem with the 320 V
voltage supply from the power board or a fault in the fan.
(see „12.3 Err 01-23 (not possible to start fan)‟, Page 62)
from lower fan motor M20. There is either a problem with the 320 V
voltage supply from the power board or a fault in the fan.
(see „12.3 Err 01-23 (not possible to start fan)‟, Page 62)
cancellation of WaveClean. The error appears once each time the
unit starts.
The unit is not ready to operate until the automatic rinse has been
completed successfully.
messages are displayed. Troubleshoot the situation. Generally, the
following reasons prevent the automatic rinse from completing:
No on-site water supply or water pressure too low.
Pressure switch fault
Fan system fault
Gas system fault (only for gas energy type)
Service instructions
Error messages
63