13.2 Err 08-02 (no gas 1 - upper burner)
Description This error message only appears if on the first gas request on
Troubleshooting Further fault message as for error message No gas
13.3 Err 08-03 (no gas 2 - lower burner)
Description This error message only appears if on the first gas request on
Troubleshooting Further fault message as for error message No gas
13.4 Err 08-04 (no flame)
Description This error message only appears if on the first gas request on
Troubleshooting Prerequisite and troubleshooting as for error message No gas
13.5 Err 08-05 (no flame 1 - upper burner)
Description This error message only appears if on the first gas request on
Troubleshooting Prerequisite and troubleshooting as for error message No gas
program start there is no response.
The fault message refers to the upper burner on 20.x pedestal units.
08-01 (no gas)‟, Page
program start there is no response.
The error message refers to the lower burner on 20.x pedestal units.
08-01 (no gas)‟, Page
program start the flame was detected (response from ionization
electrode present) and then was lost (no response from the ionization
electrode).
„13.1 Err 08-01 (no gas)‟, Page
program start the flame was detected (response from ionization
electrode present) and then was lost (no response from the ionization
electrode).
The fault message refers to the upper burner on 20.x pedestal units.
„13.1 Err 08-01 (no gas)‟, Page
Service instructions
Gas faults and error messages
76).
76).
76).
76).
(see „13.1 Err
(see „13.1 Err
(see
(see
77