Use Of Spare Relay K6 - Henny Penny FlexFusion FGE 615 Service Instructions Manual

Electric or gas gold combi oven
Hide thumbs Also See for FlexFusion FGE 615:
Table of Contents

Advertisement

Electronics

8.5 Use of spare relay K6

Description The control board has a spare relay, which allows alternative use in
Locate defective relay
Occupying the spare relay
INFORMATION
Assigning the spare relay
Exit selection
Relay overview
Relay
Connect
or
K1
X10
K1
X11
K2
X11
K4
X12
K5
X12
K6
X12
K8
X17
K17
X12
Dismantling and re-
programming
40
case of a relay failure. This is only possible with the listed relays.
Call relay test in the service menu.
Perform relay test. Locate defective relay by examining the
output voltage at the corresponding outputs on the control
circuit board.
Do rewiring according to the table.
Example: When using it for K8 (solenoid M8), rewire line from
connector X17.1 to X12.5.
In case of changes to the wiring, label or deposit note in the unit.
Call relay test in the service menu.
Select the defective relay with the left rotary knob.
Press the "+" button for 3 seconds.
A short acknowledgment tone follows.
In addition, a dot appears on the left display.
Press the "STEP" button.
No.
Description
2
Main contactor Q1
1
POS A
2
POS B
3
Solenoid valve for vapor
quenching K12
4
Siphon pump G24
5
Backup relay K6
1
Lift magnet fresh air M8
1
Circulating pump G16
After changing the control board the original state is restored. Thus,
the changed relay is not used unnecessarily.
Establish the original condition of the wiring (from X12.5 to Xx).
Call relay test in the service menu.
Select the relay K6.
Service instructions
Instruction
Re-connect the line from X10. 2 to X12. 5 and to
assign a reserve relay to it.
Re-connect the line from X11.1 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X11. 2 to X12. 5 and to
assign a reserve relay to it.
Re-connect the line from X12.3 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.4 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.5 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X17.1 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.1 to X12.5 and to
assign a reserve relay to it.