Waveclean Test (Cle) - Henny Penny FlexFusion FGE 615 Service Instructions Manual

Electric or gas gold combi oven
Hide thumbs Also See for FlexFusion FGE 615:
Table of Contents

Advertisement

5.5 WaveClean test (CLe)

Description
INFORMATION
Overview
Starting test
Abort test
Exit selection
The WaveClean test is included only in the selection, if the unit has Wave-
Clean option features.
WaveClean test program for function check.
Circulating pump
Siphon pump
Solenoid valve for filling water
Door gasket / door area sealing
CLt
Press the "START STOP" button.
Testing the cooking chamber temperature.
Automatic cooling of cooking chamber, if > 70°C.
The right display indicates the remaining time.
Siphon flush and fill.
Discharged by pump G24.
Filling by means of solenoid valve K12.
Recirculating and heating.
The circulating pump G16 is switched on.
Heating the cooking chamber to 55°C.
DynaSteam and siphon flush
DynaSteam steaming unit is switched on.
Anew siphon water exchange.
The test is completed after 30 minutes.
Press the "START STOP" button.
Automatic flushing of the siphon and test abortion.
Press the "STEP" button.
Service instructions
Service menu - unit test
0:30
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents