Service menu - unit test

5.6 DynaSteamTest (H2O)

Description The DynaSteam test allows the function test of the DynaSteam
Requirement
Overview
Starting water test
Check the water quantity Collect the water from the supply pipe with a measuring container.
Exit water test.
INFORMATION
18
steaming unit.
Calibration of the steaming unit is not possible / necessary.
Access to the water supply pipe in the cooking chamber.
Left hooking-in point or tray trolley removed.
Air baffle in the cooking chamber unlocked and unfolded.
140
H20
Press the "START STOP" button.
Display on the left shows "INI".
An automatic pre-purge begins.
Setting the amount of water with left rotary knob
Display on the left shows the amount of water in ml.
Press the "START STOP" button.
Control of the DynaSteam steaming unit.
The water runs from the water supply pipe into the cooking
chamber.
Starting water test.
After the predetermined amount of water has gone through, the
steaming unit stops automatically.
Compare amount of water with the set value. A deviation of +-
10% is within tolerance.
Press the "STEP" button.
Dual-chamber units (20.x) have two DynaSteam steaming units with parallel
control. The specified quantity of water refers to one chamber. Perform Dy-
naSteam test for each chamber separately.