5.12 Diagnostic memory (dia)

5.13 Equipment settings (Opt)

Description Adaptation of basic settings.
Overview
Selecting parameters
Changing the setting
Saving the setting
Exit selection
Overview of basic settings
No.
Basic setting
1
Temperature display
2
Altitude
5
After-running time of the
condensation hood (if present)
after opening of the cooking
chamber door
6
Time signal
7
Password settings menu
Turn the left rotary knob.
The left display flashes the first number of the basic setting,
refer to the list of basic settings.
The right display indicates the corresponding value.
Press the "START STOP" button.
Turn the right knob.
Select a new value.
Press the "START STOP" button.
The left display flashes the selected parameter.
Press and hold the "STEP" button for 3 seconds.
Changes are saved.
The centre display shows "Stor".
Press the "STEP" button.
Standard
Range of
value
adjustment
°C
0 / 1
0
0 - 3
°C
0 / 1
20
0 – 180 s
111
0 - 500
Service instructions
Service menu - unit test
Explanation
Selection of temperature display.
• 0 = °C
1 = °F
Setting of installation height above normal
zero.
• 0 = 0 – 999 m
1 = 1000 – 1999 m
2 = 2000 – 2499 m
3 = > 2500 m
Selection of temperature display.
• 0 = °C
1 = °F
Duration of audible signal in seconds.
0 = Signal off
Change of password within the setting
range.
27