12.20 Err 07-62 (lower fan fault or temperature limiter triggered)

Description The control board A1 does not receive any response via the CAN bus
Overview
DANGER
cable from the lower fan motor M20.
1 3
c
a Fan motor M20
b Power board T20 for fan motor
Connector X1 (c)
1
L1 230V
2
N
3
PE
Warning: electric shock! Danger of death!
When working on the power board, make sure that energized parts are ex-
posed. Work on these components during operation and up to 3 minutes after
enabling is not allows. Even if the motor is stopped and the appliance is de-en-
ergized, the connection terminals and components can conducted dangerous
voltage!
Service instructions
a
d
5
1
b
c Power supply X1
d Connection for fan motor X2
Connector X2 (d)
1
320V DC+
2
Ground
3
15V DC +
4
-
5
PFC
Error messages