9.2 CO2 setting

9.2.1 Checking the settings

DANGER
WARNING
INFORMATION
Prerequisite Gas connection line connected
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Some measurements on the unit require it to be at opeating temperature.
• The operating temperature is reached when the temperature in the cooking
chamber is between 130 °C —180 °C.
Checked for leaktightness outside the unit
Connection pressure checked
Checked for leaktightness inside the unit
Left side wall removed
1. Check the rated heat input at maximum output.
2. Check the rated heat input at minimum output.
3. Check the primary air quantity.
4. Check the exhaust gas values.
Preparations
1. Switch on the unit.
2. Turn the Select knob to the Settings symbol.
The indicator light illuminates.
The left display shows "PASS".
The right display flashes "----".
3. Using the right knob, set "999".
4. Press the "START STOP" button.
The left display flashes "CO2".