I/O Signals When The Quadruple Setting Is Set In Cc-Link Ver.2 (Pr. 544 = "114") - Mitsubishi Electric A800 Programming Manual

800 series, plc function
Hide thumbs Also See for A800:
Table of Contents

Advertisement

2.3.3
I/O signals when the quadruple setting is set in
CC-Link Ver.2 (Pr. 544 = "114")
The number of device points available in CC-Link communication are 32 input (RX) points (12 points for the PLC function), 32
output (RY) points (12 points for the PLC function), 8 remote register (RWr) points, and 8 remote register (RWw) points.
Remote I/O
Same as when Pr.544 = "112". (Refer to
Remote register
PLC function
Address
device number
RWwn
RWwn + 1
RWwn + 2
RWwn + 3
RWwn + 4
RWwn + 5
RWwn + 6
RWwn + 7
SD1062
RWwn + 8
SD1063
RWwn + 9
SD1064
RWwn + A
SD1065
RWwn + B
SD1066
RWwn + C
SD1067
RWwn + D
SD1068
RWwn + E
SD1069
RWwn + F
("n" indicates a value determined by the station number setting.)

Under torque control by Real sensorless vector control or vector control for the FR-A800 series (Pr.804 = "3 or 5")
page
61.)
Description
Upper 8 bits
Lower 8 bits
Monitor code
Monitor code
2
1
Set frequency/torque
command

(0.01 Hz increments)
Link
parameter
Instruction
extended
code
setting
Write data
Monitor code 3
Monitor code 4
Monitor code 5
Monitor code 6
Registers for reading data
received from the master
station.
CC-Link I/O specifications
PLC function
Address
device number
RWrn
RWrn + 1
RWrn + 2
RWrn + 3
RWrn + 4
RWrn + 5
RWrn + 6
RWrn + 7
SD1078
RWrn + 8
SD1079
RWrn + 9
SD1080
RWrn + A
SD1081
RWrn + B
SD1082
RWrn + C
SD1083
RWrn + D
SD1084
RWrn + E
SD1085
RWrn + F
CC-Link communication
Description
Upper 8 bits
Lower 8 bits
First monitor value
Second monitor value
Reply
Reply
code 2
code 1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Registers for writing data to
be sent to the master station.
63
2