Overview
3.1
Overview
3.1.1
Overview of operation
The following description is of the overview of processing performed after the inverter is turned ON and through to execution
of a sequence program.
PLC function processing can roughly be classified into the following three types.
Initial processing
Initial processing is pre-processing to execute sequence operations and is performed only once when the inverter is
turned ON or reset.
• Resets to initialize the input and output.
• Initializes the data memory (bit devices are turned OFF and word devices are set to 0).
• Performs self-diagnostic checks on such items as PLC function parameter settings and operation circuits.
NOTE
• PLC function can be checked via FR Configurator2 (Developer). (Refer to the Instruction Manual of FR Configurator2.)
Sequence program operation
Executes a sequence program written in the PLC function from step 0 through the END instruction.
END processing
End processing is post-processing to end operation processing of a sequence program once and return execution to step
0 in the sequence program.
• Performs a self-diagnostic check.
• Updates timers and counters to the present values and turns contacts on/off.
72
Sequence program